SMG-2000 Digital Phase Meter

SMG-2000 Digital Phase Meter

SMG-20000 Double Clamp Digital Phase Meter is special designed for testing voltage current and phase onsite it is in high-precision low price portable hand-held dual-channel input measuring products.

Description

 

SMG-20000 Double Clamp Digital Phase Meter is special designed for testing voltage current and phase onsite it is in high-precision low price portable hand-held dual-channel input measuring products. It’s easy to measure the phase between U-U I-I and U-I identify the inductive circuit capacitive circuit and the phase sequence of three-phase voltage detect the wiring group of transformer test the secondary circuit and bus differential protection system read the phase relationship among the CT groups of a differential protection system and check if the watthour meter was correctly wired. When testing customers do not need cut off the measured circuit which input by split core current transformer. When measuring the phase between U1 and U2 the two input circuit loop are completely insulated isolation so the possibility of misconnection is absolutely avoided which may result in short circuit or even burn the meter. The device with high-contrast LCD screen and the character in big size which helps to obtain the best visual effects.

 

Product characteristics

1. Ingenious structure easy to operate.

     A. hand held structure

     B. you should not disconnect the circuit or change the measurement range under 10mA-10A 3V-500v.

     C. use high contrast LCD character can be 25mm the screen angle can be 700 to obtain the best visual effects

     D. the function and layout of the switch are reasonable rotating can read the measuring voltage current and phase.

2. High resolution: Adopt new type patent current clamp current resolution up to 0.1mA; voltage resolution up to 0.1V.

3. Low power consumption :This product with micro power consumption design and with the function of testing the voltage of battery

 

Technique Parameters

1. Intrinsic Error

 

Reference Working Conditions

Temperature

(23±5)℃

Hunidity

(45~75)%RH

Wave forms of measured signal

sine wave、β=0.02

Frequency of measured signal

(50±0.2)Hz

Position of Measured current carrying conductor in the nipper jaw

Optional position

Amplitude range of measured signal when measuring phase

100~220V、0.5~1.5A

External reference frequency electromagnetic interference

Should be avoided

Limits of Intrinsic Error

 

1. AC Voltage

 

Table 1:Measurement Error of AC Voltage

Measure range

Resolution

Limits of intrinsic error

20V

0.01V

±(0.3%RD+0.2% Range)

200V

0.1V

±(0.3%RD+0.2% Range)

500V

1V

±(0.3%RD+0.2% Range)

Input Impedance:2MΩ for all the measure range .

Voltage input impedance of phase testing: >500KΩ

 

2. Alternating current

 

Table 2:Measurement Error of alternating current

Measure range

Resolution

Limits of intrinsic error

200mA

0.1mA

±(0.3%RD+0.2)

2A

1mA

10A

10mA

 

3. Phases U-U、U-I、I-I (see Table 3)

 

Table 3: Measurement Error of Power-frequency Phase

Range

Resolution

Limits of intrinsic error

0~360°

±2°

Impedance of input voltage loop when measuring phase of U1-U2:40KΩ

 

2. Operating error

 

Rated Working Conditions

Temperature

(0~40)℃

Humidity

(20~80)% RH

Wave forms of measured signal

Sine wave、β=0.05

Frequency of measured signal

(50±0.5)Hz

Position of Measured current carrying conductor in the nipper jaw

Optional position.

Amplitude range of measured signal when measuring phase

Phase U1-U2:30V~500V

Phase I1-I2:10mA~10.00A

Phase U1-I2 or I1-U2:10V~500V、10mA~10.00A

External reference frequency electromagnetic interference

should be avoided

Limits of Rated Working Error

Under the conditions described in 1, the limits of the rated operating error will not exceed twice of the limits of intrinsic error.

 

 

3. Other technical features

 

Display

three and half

 

Sampling rate

3 times per second

 

Power supply

Single 9V laminated cell、current of power is less than 5mA

 

Dimensions

Meter shell

192×95×55mm3

Clamp shell

140×42×20mm3

Nipper jaw

Φ7mm×9mm

Weight

Meter body

280g

Measuring clamps

2×200g

Storage Conditions

Temperature

-10℃~50℃

 

No. Name QTY
1 Host 1
2 Test line 1
3 Clamp 2
4 Case 1
5 Instruction manual 1
6 Test Report 1
7 Certification 1

 

Hot Tags: SMG-2000 Digital Phase Meter, China SMG-2000 Digital Phase Meter manufacturers, suppliers, factory, Smg 2000 Digital Phase Meter, Tag 8000 Hv Phase Tester, Smg 3000 Three Phase Meter

Next:No Information

You Might Also Like

Shopping Bags